Last Chance Black Friday Deal: Take 75% Off! Use coupon code below to secure your exam bundles! - Ends in 0d 00h 00m 00s - Coupon code: my75ex

Home > Netapp > NAHSE > NS0-094

NS0-094 NetApp Hardware Support Engineer Professional Exam Question and Answers

Question # 4

In a SAS stack of shelves, what is the topology of the connection between expander and disk?

A.

arbritrated loop

B.

point-to-point

C.

loop

D.

ring

Full Access
Question # 5

Which type of AutoSupport message would you expect to see triggered automatically when ONTAP software detects a NetApp WAFL inconsistency on an aggregate?

A.

MEDIUM ERROR DURING RECONSTRUCTION

B.

CHECKSUM ERROR

C.

WAFL INCONSISTENT USER DATA BLOCK

D.

WAFL INCONSISTENT BLOCK

Full Access
Question # 6

In the latest MANAGEMENT LOG AutoSupport message, you try to inspect the ENVIRONMENT section but find it empty.

In which section of AutoSupport can you find the reason?

A.

AUTOSUPPORT-BUDGET.XML

B.

HEADERS

C.

AUTOSUPPORT-HISTORY.XML

D.

MANIFEST.XML

Full Access
Question # 7

A storage administrator is troubleshooting a 4-node cluster, where one node is reporting “cluster port is down” alerts. The node has recently been recabled to new cluster switches. The cluster ping-cluster command shows communication failures between the affected node and its partners over the cluster network. All physical cables have been verified as properly seated and undamaged.

Which configuration is causing this problem?

A.

The MTU size on the new cluster switches is mismatched with the nodes.

B.

An incorrect gateway is defined for the management network.

C.

An incorrect intercluster LIF is configured.

D.

The SVM data LIFs are on the wrong ports.

Full Access
Question # 8

Your customer notices that their AFF A220 high-availability (HA) system is showing Single-Path HA.

How do you make the system into multipath HA?

A.

0a and 0b on both controllers should be connected.

B.

0a and 0c on both controllers should be connected.

C.

0c and 0d on both controllers should be connected.

D.

0a and 0d on both controllers should be connected

Full Access
Question # 9

At what stage is a write acknowledged to a client?

A.

when the write is present in the local node RAM and NVRAM

B.

when the write has been flushed to disk

C.

when the write is present in the NVRAM on the local node and its HA partner

D.

when the write has been flushed from NVRAM to RAM

Full Access
Question # 10

When you add a new disk to an ONTAP 9.1 system, you see an error that the disk “has raid label with version (16), which is not within the currently supported range (14-15).” What is one possible cause of this error?

A.

The disk is a non-zeroed spare.

B.

The disk firmware is too new for ONTAP software.

C.

The disk needs to be assigned to the new system.

D.

The disk was in a system with a newer version of ONTAP software

Full Access
Question # 11

You have replaced the cluster backend switches on a 4-node NetApp ONTAP cluster with new switches. After the replacement, you realize that the system shows errors for the old switches that were removed:

You also notice that system switch ethernet show shows four switches, the two old switches and the two new switches.

What action will resolve the issue?

A.

Perform a reboot of the affected node using the storage failover takeover command.

B.

Delete the old switches from the database using the system switch ethernet delete command.

C.

Clear the health alert using the system health alert delete command.

D.

Reconnect the old switches and download a support bundle using the system switch ethernet log collect command.

Full Access
Question # 12

On an AFF A700 system, a SAS stack is connected to SAS ports 2a and 2b. The system has an additional 4-port SAS card in slot 9.

How should the cabling the corrected for best practices?

A.

Use port 2a and 9a.

B.

Use port 2a and 9b.

C.

Use port 2a and 2c.

D.

Use port 2b and 9d.

Full Access
Question # 13

Which of the following scenarios could result in a NetApp WAFL inconsistency in a RAID DP aggregate?

A.

two disks failing and a block error during reconstruction

B.

rebooting a node during a disk reconstruction

C.

two disks failing within seconds of each other

D.

both party disks failing

Full Access
Question # 14

During a health check you observe that NetApp ONTAP software is reporting CRC errors on a network port from a node in the cluster.

Which component do you reseat?

A.

SFP

B.

cluster switch

C.

adapter

D.

data switch

Full Access
Question # 15

In which two sections of AutoSupport can you find information to analyze the following panic? (Choose two.)

Panic_Message: PCI Error NMI from device(s):ErrSrcID(CorrSrc(0xf00),UCorrSrc(0x18)), RPT(0,3,0):Qlogic FC 16G adapter in slot 1 on Controller

A.

HA-RASTRACE.TGZ

B.

ALL-COREDUMP.XML

C.

SSRAM-LOG

D.

PCI-HIERARCHY.XML

Full Access
Question # 16

Which two tools can be used to recover an inconsistent aggregate? (Choose two.)

A.

file check

B.

wafl_check

C.

wafl snapiron

D.

wafliron

Full Access
Question # 17

Which two of the following methods are valid ways to access a node which is not booting? (Choose two.)

A.

node management port

B.

cluster management port

C.

Service Processor

D.

serial console

Full Access
Question # 18

You are upgrading your 6-node NetApp ONTAP cluster from ONTAP 9.9.1 to 9.16.1. As part of the ONTAP software upgrade process, you need to update the cluster switches. After you update the first switch, you receive the following AutoSupport message:

Exhibit — AutoSupport Alert

vifmgr: callhome.clus.net.degraded:alert:

Call home for CLUSTER NETWORK DEGRADED:

Large MTU Packet Loss - Ping failures detected

between Node1_clus1 (169.254.2.94) on Node1

and Node2_clus2 (169.254.248.67) on Node2.

All cluster ports and interfaces are in an up/up status.

What is causing this error?

A.

ONTAP software is not at the same version on all nodes.

B.

The RCF file has not been applied to all switches.

C.

The ONTAP software version is not compatible with some of the controllers.

D.

The cluster switches have different firmware versions.

Full Access
Question # 19

Where is a kernel core file stored on a FAS9000 system that is running ONTAP 9.12.1 software?

A.

on the partner root aggregate

B.

on the root aggregate

C.

on the mailbox disk

D.

on the boot device

Full Access
Question # 20

You have replaced a failed boot device. You perform boot_recovery and receive no errors. However, when the node reboots, it reports that it has no disks.

What are two possible causes? (Choose two.)

A.

The SAS cables were incorrectly reconnected after reinstalling the motherboard.

B.

The disks that are owned by this node have been marked as failed.

C.

The node is booting a lower version of ONTAP software than was last used.

D.

The interconnect is down.

Full Access
Question # 21

A SAS connection is reporting a single PHY down.

What are the two most likely causes? (Choose two.)

A.

improperly seated cable

B.

outdated I/O module (IOM1 firmware

C.

defective cable

D.

an offline shelf in the stack

Full Access
Question # 22

Which three commands can be used to manually generate a kernel core file? (Choose three.)

A.

SP > system power cycle

B.

:: > reboot –node < node_name > –dump true

C.

:: > halt –dump true –node < node_name >

D.

:: > system node panic –node < node_name >

E.

SP > system core

Full Access
Question # 23

A node has panicked with a PCI/NMI error. Giveback has not been performed.

Which two commands should you run to collect the logs to determine the cause? (Choose two.)

A.

pelog –a –g=2

B.

show pci –v

C.

rdfile /mroot/etc/log/SSRAM

D.

event log show

Full Access
Question # 24

Following an unexpected takeover, the taken-over node is waiting for giveback. The administrator plans to perform a giveback with the option –cfo–only true.

What happens if this option is used?

A.

Only a simulation of the giveback is performed.

B.

Only the root aggregate is given back.

C.

Only SVM root volumes are sent back

D.

Only the data aggregates are sent back.

Full Access