H20-923_V1.0 HCSP-Field-Data Center Facility V1.0 Question and Answers

Question # 4

Which of the following control modes can be used for temperature and humidity control of smart cooling products?

A.

Cold aisle

B.

Supply air

C.

Return air

D.

Hot aisle

Full Access
Question # 5

In alarm management, the status can be identified by masking rules.

A.

Invalid

B.

Standard

C.

Maintenance

D.

Valid

Full Access
Question # 6

Which of the following can be used to start the inverter of the UPS5000-H?

A.

UPS WebUI

B.

ECC

C.

UPS LCD

D.

NetEco

Full Access
Question # 7

When the outdoor unit is installed at a position higher than the indoor unit, install an oil trap every five to six meters in the vertical direction along the gas pipe to ensure system reliability.

A.

True

B.

False

Full Access
Question # 8

Which of the following statements are true about the routine maintenance of a UPS?

A.

Environment check: Check whether the temperature and humidity of the equipment room meet the recommended environment requirements. Check whether the equipment room is clean and tidy.

B.

UPS status check: Check whether the UPS works in normal mode, whether an alarm is generated, and whether the UPS is in a proper load.

C.

Routine maintenance of vulnerable components: Periodically check the UPS fan operation, whether there is noise, and whether the rotation speed is abnormal.

D.

If there is no alarm on the UPS panel, do not need to check the installation environment, temperature, and humidity onsite.

Full Access
Question # 9

Which of the following is not a scenario-based solution for Huawei data center products?

A.

FusionDC800

B.

FusionDC1000

C.

FusionModule500

D.

FusionModule2000

Full Access
Question # 10

After the unit is powered on for the first time, it enters the compressor preheating state. To quickly perform power-on commissioning, you can manually shut down the compressor preheating.

A.

True

B.

False

Full Access
Question # 11

Which of the following statements is false about the advantages of the free cooling solution for data centers?

A.

The current technology is not mature enough and should be used with caution.

B.

Has many use cases in the industry.

C.

Directly uses the cooling capacity of the outdoor cooling source, resulting in ultra-low energy consumption.

D.

Makes full use of the seasonal temperature difference of air and water sources.

Full Access
Question # 12

Which of the following statements are true about the industry trend of the data center cooling systems?

A.

Liquid cooling systems are widely used in high-density solutions.

B.

Cloud + AI – data centers enter a new energy-saving era.

C.

Evaporative cooling systems become the main solution for large data centers.

D.

Higher inlet and outlet water temperatures are the trend of large data center cooling.

Full Access
Question # 13

Huawei-developed intelligent rPDU (PDU2000M) can replace the original UIM20A expansion module. The rPDU can connect to the cabinet temperature/humidity sensors, smart U space managers, and door status sensors.

A.

True

B.

False

Full Access
Question # 14

If the SPD indicator of a smart module is green, the SPD is running properly. If the SPD indicator is red, the SPD is faulty and must be replaced immediately.

A.

True

B.

False

Full Access
Question # 15

The default port number for logging in to the NetEco is

A.

32804

B.

32805

C.

31943

D.

31945

Full Access
Question # 16

The maintenance bypass switch cannot be turned on when the UPS5000-H works in normal mode.

A.

True

B.

False

Full Access
Question # 17

The NetEco service program backend can be accessed through the iBMC port.

A.

True

B.

False

Full Access
Question # 18

Which of the following statements are true?

A.

When the UPS works in normal mode, you can directly turn on the maintenance bypass switch.

B.

When the UPS works in static bypass mode, if the mains input outage occurs suddenly, the UPS automatically switches to battery mode.

C.

Huawei UPS5000-H is a modular UPS. If a module fails, it can be replaced online.

D.

When mains and bypass input of the UPSs share one power source, if mains outage occurs, the UPS cannot work in bypass mode.

Full Access