When delivering a Huawei OceanStor Pacific storage project, a Huawei engineer vigorously promoted the SmartEncryption feature of scale-out storage to customers. Which of the following statements is false about this feature?
The_____feature provided by the OceanStor Pacific series storage system supports OPS and bandwidth upper limit control based on namespaces, accounts, and client IP addresses.
In a flash storage system, the ports of the cascading interface module or onboard cascading ports on the controller enclosure can only connect to port PI on the disk enclosure.
Huawei OceanStor Pacific series is an intelligent scale-out storage product that supports large-scale scale-out and delivers high reliability. Which of the following statements are false about the product’s reliability?
A bank customer purchases several Huawei flash storage devices to store upper-layer Oracle database service data. If an Oracle database fault occurs, engineers need to collect Oracle alert log files to locate the fault. Which of the following commands cannot be used to query the alert log path?
An industry customer has purchased several Huawei flash storage devices for service deployment. An engineer wants to configure the HyperSnap feature on the storage devices. However, during the configuration, the engineer discovers that snapshots cannot be created for an existing protection group. The possible cause is that the storage pool where the source LUNs in the protection group reside has no available capacity.
To prevent misoperations from affecting services, a storage system controls user operation permissions and scopes based on user levels and roles. Which of the following is not a tenant management user role in the storage system?
In Huawei flash storage. If you want to apply the HyperCDP feature to a LUN, you are advised to reserve 5% to 10% of the LUN capacity in the storage pool to which the I UN belongs for storing HyperCDP object data, and configure a protection capacity threshold for the storage pool to stop creating HyperCDP objects or even automatically delete HyperCDP objects when the storage pool capacity is insufficient.
After purchasing a Huawei OceanStor Dorado series storage system, a customer needs to configure basic storage services in the storage system. Which of the following operations are optional in the basic service configuration?
A financial customer has purchased several Huawei OceanStor Dorado series storage devices for mission-critical service deployment. SmartMigration is configured to migrate services from a source LUN to a target LUN without interrupting host services. Which of the following statements about this feature is false?
During routine O&M, an engineer finds that the system time of multiple Huawei flash storage devices Is Incorrect, and needs to correct the system time. Which of the following Is not a possible impact of changing the system time?
An industry customer has purchased a Huawei OceanStor Pacific scale-out storage system for service deployment. An engineer configures NFS file sharing on the storage system through NFSv4.0. Which of the following commands can the engineer use to switch the user view to the developer view on the command line interface (CLI)?
Assume a government office purchases a Huawel OceanStor Pacific 9550 storage device. During an Inspection, an engineer notices the IAN on motherboard (LOM) optical port Indicator on the rear panel of the device Is steady yellow. This indicates that data is being transmitted at a rate of 25 Gbit/s.
A government customer has purchased several Huawei OceanStor Dorado 18000 series storage devices for service deployment, and an engineer needs to create storage pools on the storage system. However, before doing so, the engineer must configure LUNs and LUN groups, and create the mapping between the LUN groups and host groups.
A school customer has purchased two Huawei flash storage devices and deployed them in different equipment rooms. To ensure data and service reliability, an engineer deploys the HyperReplication (remote replication) feature on the storage devices. After a fault recovery, the engineer needs to manually synchronize data to restore the pair relationship between the primary and secondary LUNs. What is the current running status of the remote replication pair?
SPC certification is a SAN performance test benchmark for third-party evaluation. Which of the following statements is true about SPC certification scenarios?
During routine inspection, an engineer of a bank finds that an interface module of a Huawei flash storage device is faulty. In this case, the engineer can directly remove and insert the interface module without any pre-operations.
Huawel OceanStor Pacific series products provide object storage capabilities and support cross-site disaster recovery (DR). Which of the following statements about object storage cross-site DR is false?
When demarcating a performance issue of Huawei flash storage, engineer A finds that the latency observed on the compute side is much longer than that on the storage side. This indicates that the issue most possibly occurred on the storage, for example, the disk performance upper limit has been reached.
The performance of a storage system can be measured by multiple indicators. In application scenarios where the I/O size is greater than or equal to 64 KB, the ________ performance indicator is the main concern for storage performance.
Before configuring services for Huawei flash storage, you need to Initialize the system. Which statement about the initialization is false?
Huawei scale-out storage provides file services using the distributed parallel client (DPC) to meet the requirements of high-performance computing (HPC) scenarios. Which of the following statements about the DPC is false?
During routine management of Huawei flash storage, an engineer can use the "show license_active" command to query information about activated licenses.
In Huawei flash storage, the integrated I/O stack of SAN and NAS can be divided into the storage pool layer, space management layer, and data service layer. Which of the following are performance concerns of the space management layer?
The service system needs to be backed up before performance optimization b performed on Huawei flash storage, and up to two optimization configurations can be changed at a time.
A government customer has purchased two Huawei flash storage devices and deployed them in different data centers for running remote replication services. When a primary/secondary switchover is performed for the remote replication pair, the primary and secondary sites record the data changes. When the secondary site becomes the primary site following the primary/secondary switchover, all data will be synchronized between the primary and secondary sites.
In Huawei flash storage, the administrator rote has full control permissions on storage devices. The administrator can power on, power off, and restart devices and create users of different roles.
A financial customer has purchased several Huawei OceanStor Pacific 9550 storage systems. When configuring basic object services on the storage systems, an engineer discovers that the object service cannot be enabled for storage nodes. Which of the following is not a possible cause?