H13-624_V5.5 HCIP-Storage V5.5 Question and Answers

Question # 4

A school has purchased two Huawei OceanStor Pacific series storage devices for service deployment. An engineer wants to configure the distributed parallel client (DPC) on the storage devices. Which of the following statements is false about the engineer's configuration?

A.

If upper-layer services require high data security, the engineer needs to set the storage pool type to "Self-encrypting" when creating a converged storage pool.

B.

Before creating a converged storage pool, the engineer must enable the file service for nodes on DeviceManager.

C.

When creating a namespace, the engineer needs to select a security style and application type.

D.

When the storage network is a Remote Direct Memory Access over Converged Ethernet (RoCE) network, the engineer can run the "systemctl stop lldpad.service" command to disable the lldpad service.

Full Access
Question # 5

A financial customer has purchased a Huawei flash storage system for service deployment. An engineer configures the HyperCDP feature on the storage system and wants to create a HyperCDP schedule. Which of the following commands can the engineer use?

A.

create hyper_cdp_schedule general

B.

add hyper_cdp_schedule fs

C.

create fs_hyper_cdp general

D.

change hyper_cdp_schedule enabled

Full Access
Question # 6

In Huawei flash storage, the integrated I/O stack of SAN and NAS can be divided into the storage pool layer, space management layer, and data service layer. Which of the following are performance concerns of the space management layer?

A.

Cache hit ratio of hot metadata

B.

CPU usage of metadata background management

C.

Whether failover is enabled for protocol receiving threads

D.

Hit ratio of the prefetch algorithm

Full Access
Question # 7

Which statements are false about software Installation of Huawei OceanStor Pacific series storage systems?

A.

To install the Distributed Parallel Client (DPC), the switch configuration is required before the installation regardless of whether the low level design (LLD)- or wizard-based installation mode is selected.

B.

To interconnect with FusionCompute during block service installation, storage and compute nodes must be deployed in converged mode, and the management nodes must be deployed in the virtualization environment.

C.

To interconnect with Huawei Cloud Stack during block service installation, storage and compute nodes must be deployed in converged mode, and the management nodes must be deployed in the virtualization environment.

D.

To install the file service in the standard protocol scenario, the switch configuration is not required throughout the entire installation process.

Full Access
Question # 8

The service system needs to be backed up before performance optimization b performed on Huawei flash storage, and up to two optimization configurations can be changed at a time.

A.

TRUE

B.

FALSE

Full Access
Question # 9

Similar to the alarm analysis method, the replacement method can be used to locate and rectify any type of faults for Huawei converged storage, and has no special requirement for maintenance personnel.

A.

TRUE

B.

FALSE

Full Access
Question # 10

A financial customer has purchased two Huawei flash storage devices and installed them in two equipment rooms of a local data center to deploy HyperMetro services. During quorum server network planning, only 10GE quorum links can be used when a single quorum server is deployed. 25GE and Fibre Channel networks cannot be used.

A.

TRUE

B.

FALSE

Full Access
Question # 11

An engineer can use the ______ tool to install software for Huawei storage systems. This tool can collect and evaluate storage compatibility information in one-stop mode and supports batch installation of the UltraPath software, improving the software installation efficiency.

Full Access
Question # 12

Assume a financial customer purchases a Huawei OceanStor Pacific scale-out storage system for future service deployment. Which statement is false about software installation of the storage system?

A.

During block service installation, if management nodes are deployed where compute and storage nodes are converged, the number of vCPUs on each converged compute and storage node must be greater than or equal to 20.

B.

During block service installation, if converged deployment of storage and compute nodes is required, the difference between the disk quantities on any two nodes in the same storage pool cannot be greater than 2 or 30% of the disk quantity on the node having most disks.

C.

If wizard-based software installation is used, an engineer must manually add nodes, configure networks, and create a control cluster on DeviceManager, and then install the OceanStor Pacific series software.

D.

To install the Distributed Parallel Client (DPC), the memory required for running the DPC software on a compute node must be greater than or equal to 20 GB.

Full Access
Question # 13

An industry customer has purchased a Huawei OceanStor Pacific scale-out storage system for service deployment. An engineer configures NFS file sharing on the storage system through NFSv4.0. Which of the following commands can the engineer use to switch the user view to the developer view on the command line interface (CLI)?

A.

change domain ad_manager operation=develop

B.

change dns general address=develop

C.

change user_mode current_mode user_mode=developer

D.

change nas_Idap advanced_config

Full Access
Question # 14

When delivering a scale-out storage project, Huawei engineers introduced the OceanStor Pacific parallel file system service to the customer. Which of the following statements is false about the service?

A.

Small I/Os are aggregated in the cache and then written to disks, achieving an ideal latency and improving the utilization of small files.

B.

Fixed-length large-granularity indexes are used to ensure sequential read/write performance of large I/Os.

C.

Large I/Os can be directly forwarded to the home node for processing, eliminating the overhead of scale-out locks and greatly reducing the read/write latency of large I/Os.

D.

In terms of I/O flow, large I/Os are written to disks in passthrough mode, improving the bandwidth capability.

Full Access
Question # 15

Assume a bank customer purchased several Huawei flash storage devices for deploying the document Imaging service. This service mainly involves random large I/Os, more read operations than write operations, and many metadata operations, with obvious hot and cold data characteristics.

A.

TRUE

B.

FALSE

Full Access
Question # 16

SPC certification is a SAN performance test benchmark for third-party evaluation. Which of the following statements is true about SPC certification scenarios?

A.

SPC-2 applies to scenarios where random small I/Os are quickly responded.

B.

SPC-1 applies to scenarios of sequential large I/O access.

C.

SPC-2 applies to scenarios of sequential large I/O access.

D.

SPC-2 is used to test the SAN array performance in the OLPT, database, and email application scenarios.

Full Access
Question # 17

During routine O & M, an engineer finds that the system time of multiple Huawei flash storage devices Is Incorrect, and needs to correct the system time. Which of the following Is not a possible impact of changing the system time?

A.

If the new device time is later than the deadline for saving historical performance data, the system will no longer save historical performance data.

B.

Changing the device time will affect the life spans of disks and controllers, which may trigger alarms indicating that the hardware life span expires or hardware is aging.

C.

If the new system time is later than the user-defined password expiration date, the system may force the user to change the login password.

D.

If the new device time is later than the certificate validity period, the certificate will expire.

Full Access
Question # 18

When delivering a Huawel OceanStor Pacific scale-out storage project, an engineer introduced the end-to-end data Integrity check technology of scale-out storage to the customer. Which of the following statements are false about this technology?

A.

This technology enables the storage system to implement periodic background data integrity check. When the service load is heavy or service access is frequent, the system automatically starts periodic background data integrity check and self-healing.

B.

For silent data scenarios such as bit change and read offset, the end-to-end data integrity check technology supports logical block addressing (LBA) check of clusters and hosts.

C.

Block, NAS, and object services support end-to-end data integrity check, but the HDF5 service does not.

D.

In this technology, write requests are checked at the system entry (virtual block service). User data is checked again in the object storage device (OSD) before being written to disks. Data Is written to disks only after the data integrity check succeeds.

Full Access
Question # 19

To improve service availability, a manufacturing customer has purchased multiple Huawei flash storage devices and deployed active-active and remote backup services on them. In this case, if the link bandwidth is too low or the concurrent processing capability is insufficient, the active-active service may be faulty, but the remote backup service is not affected.

A.

TRUE

B.

FALSE

Full Access
Question # 20

When delivering a flash storage project, Huawei engineers Introduced the SmartMuIti-Tenant feature of flash storage to the customer. Which of the following statements are true about SmartMulti Tenant?

A.

A super administrator can force itself, other super administrators, lightweight directory access protocol (LDAP) users, or LDAP user groups to change their passwords upon the next login.

B.

After a system is upgraded to support the SmartMulti-Tenant feature, all LUNs, file systems, and ports in the original system are allocated to the internal system vStore "System_vStore."

C.

To query system role information, the customer can run the "show role system" command.

D.

In flash storage, only a super administrator can modify vStore information, and the internal system vStore "System_vStore" cannot be modified.

Full Access
Question # 21

The backup and archiving scenario mainly involves sequential read of large I/Os, where there are more read I/Os than write I/Os and hot data areas are obvious. The service characteristics of this scenario are the same as those of the database OLAP scenario.

A.

TRUE

B.

FALSE

Full Access
Question # 22

A government customer has purchased several Huawei OceanStor Dorado 18000 series storage devices for service deployment, and an engineer needs to create storage pools on the storage system. However, before doing so, the engineer must configure LUNs and LUN groups, and create the mapping between the LUN groups and host groups.

A.

TRUE

B.

FALSE

Full Access
Question # 23

A company has purchased multiple Huawei OceanStor Pacific series devices to deploy the remote replication service. During routine operation and maintenance, an administrator needs to manage the replication cluster. Which of the following statements are true about a replication cluster?

A.

Capacity reduction of a replication cluster can be performed only when the number of nodes is greater than or equal to 4.

B.

The name of a replication cluster for which cross-site disaster recovery is enabled cannot be changed, but the replication cluster can be deleted.

C.

When the capacity of a replication cluster is expanded, the replication network can share the same subnet with other networks.

D.

When an IP address of a replication cluster is changed, if a node in the replication cluster uses multiple ports and different replication ports are configured with IP addresses in the same network segment, the original policy-based route must be deleted before configuring a new policy-based route.

Full Access
Question # 24

When deploying a Huawei converged storage system, engineer A uses the UltraPath software. Which of the following statements are false about the load balancing algorithms of UltraPath?

A.

The min-queue-depth algorithm refers to the minimum queue depth algorithm. UltraPath is configured with this algorithm by default.

B.

Round robin is a min-task algorithm and can be used in scenarios where service I/O model data blocks delivered by the host are large.

C.

The min-task algorithm is a round robin algorithm and can be used in scenarios where the service I/O models delivered by the host have little difference.

D.

The algorithms fall into three types: min-queue-depth, round-robin, and min-task.

Full Access
Question # 25

An industry customer has purchased two Huawei OceanStor Pacific scale-out storage devices and deployed them in different equipment rooms. Now an engineer wants to configure the HyperMetro feature on the two devices in static priority mode. Equipment room A is the preferred site. After the link between the two storage devices is down, what is the running status of the HyperMetro pair and what is the arbitration result?

A.

The running status of the HyperMetro pair is "Normal". The arbitration result is that the volume in equipment room A is inaccessible and that in equipment room B continues providing services.

B.

The running status of the HyperMetro pair is "To be synchronized". The arbitration result is that the volume in equipment room A continues providing services and that in equipment room B stops providing services.

C.

The running status of the HyperMetro pair is "Normal". The arbitration result is that the volumes in equipment rooms A and B continue providing services.

D.

The running status of the HyperMetro pair is "To be synchronized". The arbitration result is that the volume in equipment room A is inaccessible and that in equipment room B stops providing services.

Full Access
Question # 26

When delivering a flash storage project, Huawei engineers introduced the multi-tenant feature of flash storage to the customer. This feature isolates service data. Although different tenants cannot access each other’s LUNs, they can access each other’s file system.

A.

TRUE

B.

FALSE

Full Access
Question # 27

In OceanStor Pacific series storage systems, if a node or disk is faulty, data reconstruction in the disk pool can be automatically performed after 15 minutes.

A.

TRUE

B.

FALSE

Full Access
Question # 28

In actual service scenarios, the HyperMetro feature of Huawei OceanStor Pacific series supports incremental synchronization. If a site fails, the site that wins arbitration continues providing services, and I/O requests change from the dual-write state to the single-write state. After the faulty site recovers, data generated during the fault can be synchronized to the recovered site.

A.

TRUE

B.

FALSE

Full Access
Question # 29

The _____ feature provided by the OceanStor Pacific series storage system supports OPS and bandwidth upper limit control based on namespaces, accounts, and client IP addresses.

Full Access
Question # 30

Assume a financial customer purchased a Huawei flash storage device for service deployment. During storage system Initialization, an engineer needs to configure security policies for the storage system. Which of the following is not a policy for security configuration?

A.

Login policy

B.

Blocklist and trustlist policies

C.

User account audit policy

D.

Account policy

Full Access
Question # 31

When learning the SmartVirtualization feature of Huawei flash storage, a new employee is not familiar with eDevLUNs and external LUNs. Which of the following statements are true about the eDevLUNs and external LUNs?

A.

An eDevLUN consists of actual data and metadata. The storage space required by metadata is provided by the heterogeneous storage system, and the physical space required by actual data is provided by the local storage system.

B.

If the administrator has not configured any value-added feature for eDevLUNs, each eDevLUN occupies small space in the storage pool of the local storage system.

C.

eDevLUNs belong to storage pools created in the local storage system.

D.

eDevLUNs can be created regardless of whether external LUNs are normal.

Full Access
Question # 32

If Huawei scale-out storage software is installed in low level design (LLD) mode, engineers need to use the ________ installation and deployment tool to plan nodes, networks, and clusters and export the configuration file for subsequent installation and deployment.

Full Access
Question # 33

In Huawei backup storage OceanProtect X3000, data reduction supports fixed-length (^duplication by default, but does not support variable-length (^duplication. Therefore, fixed-length ded11plication Is mainly used in the backup field.

A.

TRUE

B.

FALSE

Full Access
Question # 34

Huawei OceanStor Pacific series storage systems support the _______ client access mode. This mode allows a single client to connect to multiple storage nodes and supports MPI-I/O access. (Enter an acronym.)

Full Access
Question # 35

Assume a financial customer purchases several Huawei scale-out storage devices for service deployment. Unstructured services require multiple network planes. Which statement about the network planes is false?

A.

The internal management network is used for communication between storage and management nodes, including deployment and upgrade, resource configuration, performance alarm reporting, and certificate and key update.

B.

For the file service in the Distributed Parallel Client (DPC) scenario, the back-end storage network is available for communication with compute nodes to process communication data between the DPC and Object Storage Device (OSD).

C.

The management network is used for system management and maintenance. It is connected to the customer’s management network.

D.

The service network is connected to the customer’s application system and accesses the storage through the S3, HDFS, NFS, CIFS, and POSIX interfaces.

Full Access
Question # 36

An airport customer has purchased several Huawei OceanStor Pacific scale-out storage devices for service deployment. To ensure service reliability, an engineer has configured the HyperReplication feature on the storage devices and established a remote replication pair between the namespaces of the primary and secondary storage systems. Which of the following statements is true about the running statuses of the remote replication pair?

A.

If the running status of the remote replication pair is "Synchronizing", this indicates that data is being synchronized from the primary namespace to the secondary namespace. In this case, the engineer can enable the protection for secondary resources on the secondary storage system.

B.

If the running status of the remote replication pair is "Interrupted", this indicates that an internal I/O error has occurred or the remote replication link is down. As a result, the pair relationship is interrupted.

C.

If the running status of the remote replication pair is "Split", this indicates that the remote replication link is down or an internal I/O error has occurred. In this case, the pair cannot be synchronized or deleted.

D.

If the running status of the remote replication pair is "To be recovered", this indicates that the internal I/O error of the remote replication pair has been rectified. Data consistency between the primary and secondary storage systems is guaranteed by automatic synchronization.

Full Access
Question # 37

During routine management of Huawei flash storage, an engineer can use the "show license_active" command to query information about activated licenses.

A.

TRUE

B.

FALSE

Full Access