Spring Sale Special - Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: mxmas70

Home > Pure Storage > FAIS > FlashArray-Implementation-Specialist

FlashArray-Implementation-Specialist Pure Certified FlashArray Implementation Specialist (FAIS) Exam Question and Answers

Question # 4

Once the new Purity firmware has been installed using the pureinstall command, what step is required to commit the new version?

A.

Reboot the controller

B.

Reboot the array

C.

Log out of the controller

D.

Run pureinstall --commit

Full Access
Question # 5

After rebooting a controller, which command should an Implementation Engineer run to verify all the Purity services have started successfully?

A.

pureadm

B.

pureadm list

C.

pureadm status --all

Full Access
Question # 6

Which FlashArray//XL DirectMemory Modules (DMMs) configuration condition is true?

A.

DMMs cannot be installed in a DirectFlash Shelf (DFS).

B.

DMMs are only compatible with //XL 170.

C.

DMMs use different drive slots to regular DirectFlash modules.

D.

DMMs are required for baseline array initialization.

Full Access
Question # 7

An Implementation Engineer is installing a FlashArray//XR4 and needs to add an extra card to support a second DirectFlash Shelf.

What will be the resulting pair of interfaces?

A.

ETH6 and ETH7

B.

ETH5 and ETH6

C.

ETH4 and ETH5

D.

ETH8 and ETH9

Full Access
Question # 8

During a FlashArray installation, when should the Implementation Engineer run pureinstall on a controller?

A.

After puresetup has been run with initial configuration set.

B.

After confirming no hosts are connected to the controller.

C.

Prior to initializing/configuring the controller.

D.

Immediately after completing the data migration phase.

Full Access
Question # 9

Which command should an Implementation Engineer use to allow Support access to an array?

A.

purearray connect --remoteassist

B.

purearray remoteassist

C.

purearray remoteassist --connect

Full Access
Question # 10

What command should the Implementation Engineer run to view NVRAM install and update status?

A.

puredrive list

B.

purearray list

C.

purehw list --all

Full Access
Question # 11

An Implementation Engineer is onsite to replace a 22TB data pack with a new 91TB (10 x 9.1TB) data pack in a FlashArray//X90R5 Gen 2. The array is at 90% capacity. It currently has 22TB (10 x 2.2TB) in slots 0-9 and 63TB (14 x 4.5TB) in slots 10-23, configured as two separate write groups.

What is a supported method to proceed with the planned capacity migration?

A.

Add the new datapack into slots CH0.BAY24 - CH0.BAY28 and start the EVAC of the drives in slots 0-9. Install the remaining drives after the EVAC completes.

B.

Install a swing shelf, add the new data pack to the swing shelf, and evacuate the old 22TB (10 x 2.2TB) pack.

C.

Evacuate the drives from slots 0-9 into remaining capacity, then install the new data pack into those slots.

D.

Remove the 22TB data pack instantly and rebuild the missing data onto the new 91TB drives from parity.

Full Access
Question # 12

On FlashArray models that use standard DFMs instead of DFMDs, which NVRAM bays are always populated?

A.

NVB0 and NVB1

B.

NVB0 and NVB2

C.

NVB0 and NVB3

D.

NVB1 and NVB2

Full Access
Question # 13

Prior to installing a new FlashArray controller, which terminal display settings must the Implementation Engineer configure?

A.

8-E-1, Xon/Xoff flow control, 115,200 baud

B.

8-N-1, No flow control, 115,200 baud

C.

8-N-1, Xon/Xoff flow control, 38,400 baud

D.

7-E-1, Hardware flow control, 9,600 baud

Full Access
Question # 14

When using FA File, where can the Implementation Engineer manage directories?

A.

Storage > File Systems

B.

Settings > Access > Directory Services

C.

Analytics > Performance > Directories

Full Access
Question # 15

Which cards are required to connect a DirectFlash Shelf to an FlashArray//XLR5?

A.

2-Port 100GbE iSCSI/RoCE

B.

2-Port 50GbE

C.

2-port 200GbE Ethernet/RoCE

Full Access
Question # 16

An Implementation Engineer is onsite to install a new DFM data pack (DP) to CH0.BAY10-CH0.BAY19 of a FlashArray. After adding the drives to the chassis, which command should the Implementation Engineer run to verify if the new DP is in a wide write group?

A.

find_drive.py

B.

puredb list drives

C.

puredrive list --pack CH0.BAY10

Full Access
Question # 17

When accessing the FlashArray GUI, which management IP address is recommended for use?

A.

CT1 management IP

B.

CT0 management IP

C.

Virtual management IP

D.

Replication management IP

Full Access
Question # 18

A data pack has been installed and the puredrive list command shows the drives in “unadmitted” status. Which command should be used to complete the admission?

A.

puredrive add

B.

puredrive admit

C.

purearray drive admit

Full Access
Question # 19

What is the redundancy of the FlashArray//XL PSUs?

A.

1+1

B.

2+2

C.

3+1

Full Access
Question # 20

On a FlashArray//XR20R2/3 Fibre Channel (FC) array, what is the default type and placement of the PCIe FC card?

A.

2-port in slot 0

B.

2-port in slot 2

C.

4-port in slot 0

Full Access
Question # 21

On FlashArray//XL, which slots support a 4-port FC card?

A.

5 and 8

B.

3 and 8

C.

2 and 8

Full Access
Question # 22

After upgrading Purity during a new installation, which command should an Implementation Engineer run to determine what version of Purity will be loaded at the next boot of the FlashArray?

A.

purearray list --controller

B.

pureversion -a

C.

pureboot list

Full Access
Question # 23

FlashArray//C and //E models use which flash storage architecture, identifiable by gray tabs on the DirectFlash Module carriers?

A.

TLC Flash

B.

QLC Flash

C.

SLC Flash

D.

MLC Flash

Full Access
Question # 24

An Implementation Engineer has completed cabling a DirectFlash Shelf (DFS) to the FlashArray. Which command should the Implementation Engineer run to verify that the cabling was completed correctly?

A.

storage_view.py enclosures

B.

storage_view.py list

C.

storage_view.py config

Full Access
Question # 25

What slot does a PCIe SAS card need to be installed in a FlashArray//XR2/3?

A.

0

B.

1

C.

2

Full Access
Question # 26

A customer wants to expand the capacity of their FlashArray//X10 from 5/5 to 11/11. Which is the correct action to take?

A.

Evacuate and swap one pack at a time.

B.

Perform a drive-by-drive swap of the modules.

C.

Install a swing shelf with loan capacity to evacuate to.

Full Access
Question # 27

An Implementation Engineer needs to upgrade Purity to version 6.9.2 on a FlashArray. The .ppkg file was too large to fit on a USB stick as a single file and has been copied to the array as two split files.

How should the Implementation Engineer join the files into a single file to be installed?

A.

join /home/puresetup/purity_6.9.2_202510142333+afllcdel386b.ppkga* -o /home/puresetup/purity_6.9.2_202510142333+afllcdel386b.ppkg

B.

cat /home/puresetup/purity_6.9.2_202510142333+afllcdel386b.ppkga* > /home/puresetup/purity_6.9.2_202510142333+afllcdel386b.ppkg

C.

tar -xf /home/puresetup/purity_6.9.2_202510142333+afllcdel386b.ppkga* /home/puresetup/purity_6.9.2_202510142333+afllcdel386b.ppkg

D.

zip -m /home/puresetup/purity_6.9.2_202510142333+afllcdel386b.ppkg /home/puresetup/purity_6.9.2_202510142333+afllcdel386b.ppkga*

Full Access
Question # 28

What is the maximum number of DirectFlash Shelves supported for FlashArray//XL?

A.

2

B.

3

C.

4

Full Access
Question # 29

During an NDU, when is the Implementation Engineer required to install additional NVRAM modules in slots 2 and 3?

A.

Upgrading a FlashArray//X50R3 to a FlashArray//X70R4

B.

Upgrading a FlashArray//X50R3 to a FlashArray//X50R4

C.

Upgrading a FlashArray//X70R4 to a FlashArray//X90R4

D.

Upgrading a FlashArray//X10R3 to a FlashArray//X20R4

Full Access
Question # 30

On a FlashArray//XR4, which port is enabled for the management service by default?

A.

ETH2

B.

ETH4

C.

ETH0

Full Access
Question # 31

Which Pure1 app functionality requires that a user is on their internal company network?

A.

Manage support cases

B.

View array telemetry

C.

Open Remote Assist

D.

Monitor capacity utilization

Full Access
Question # 32

How many chassis capacity drive slots come standard on a FlashArray//X Gen 2 chassis?

A.

28 slots

B.

20 slots

C.

24 slots

D.

40 slots

Full Access
Question # 33

A customer has submitted a Pure Engagement Request (PER) / Implementation Workbook (IWB) and the stated array name is "123".

What is the issue with this array name?

A.

Array name cannot start with a digit.

B.

Array name must be 4 characters or more.

C.

Array name must be alphanumeric.

D.

Array name cannot contain hyphens.

Full Access
Question # 34

FlashArray//C and //E models use which flash storage architecture, identifiable by gray tabs on the DirectFlash Module carriers?

A.

SLC Flash

B.

QLC flash

C.

TLC Flash

Full Access
Question # 35

A customer needs to have arrays installed and configured with ActiveCluster and ETH replication. The installation document contains 3 IP addresses. How many additional IP addresses are needed?

A.

4

B.

5

C.

6

Full Access
Question # 36

An Implementation Engineer is installing a FlashArray//XL chassis with two DirectFlash Shelves. What is the minimum rack space required for this installation?

A.

9U

B.

11U

C.

12U

Full Access
Question # 37

Which command should the Implementation Engineer run to remove a tunable from the primary controller?

A.

puretune local --unset

B.

puretune --unset

C.

pureadm tune --unset

D.

puretune remove

Full Access
Question # 38

Refer to the exhibit.

During the puresetup portion of the new controller setup of an NDU, the Implementation Engineer gets an error message regarding missing or unassigned network interfaces.

What action should the Implementation Engineer take next?

A.

Identify which services will be affected, and then re-run the puresetup command with the affected ports included.

B.

Identify which services will be affected, stop the process, and open a case with a TSE before moving forward.

C.

Continue with the setup process and manually add the affected ports once it is complete.

D.

Re-seat the network cables and reboot the controller to clear the error.

Full Access
Question # 39

What is the minimum AC voltage required to operate a FlashArray//X20R4 array?

A.

90

B.

180

C.

220

Full Access
Question # 40

When should a FlashArray support case be opened?

A.

Once an issue arises

B.

Once install is completed

C.

Before starting install

Full Access
Question # 41

Which user does an Implementation Engineer use when preparing for the Purity upgrade to complete a HWNDU?

A.

pureuser

B.

puresetup

C.

pureinstall

D.

root

Full Access
Question # 42

Support requests a powercycle on a newly-installed FlashArray. What is the correct way to perform this action?

A.

Push the power button on each controller.

B.

Unplug the cable on each power supply.

C.

Run purearray reboot.

Full Access
Question # 43

An Implementation Engineer is planning to add a DirectFlash Shelf to a FlashArray//XL with an existing DirectFlash Shelf. Which PCIe slot must be used for shelf connectivity?

A.

0

B.

4

C.

6

Full Access
Question # 44

An Implementation Engineer is performing a FlashArray//X to FlashArray//XL HWNDU. After rebooting a controller, the new controller fails to reach a ready state. Which command should the Implementation Engineer run to resolve the issue?

A.

ha_sync.py --resync ipneigh

B.

hardware_check.py

C.

firewall.py --add ha rcima eth23

Full Access
Question # 45

An Implementation Engineer needs to run the puresetup replace procedure on a FlashArray//XR5 during a controller upgrade. What command should the engineer run to identify the array model?

A.

hwconfig --all

B.

pureversion -a

C.

hwconfig --model

Full Access
Question # 46

For a new FlashArray installation, a customer's network team has NOT provisioned network ports for management connectivity. How Will this affect the installation process?

A.

The array's data will be inaccessible.

B.

Management connectivity is required for installation.

C.

The customer Will be unable to login to the array.

Full Access
Question # 47

Which enablement feature will cause Mirrored Write statistics to appear in the Analysis section of the FlashArray Purity 6.x GUI?

A.

FA File

B.

ActiveCluster (AC)

C.

ActiveDR

Full Access
Question # 48

The Customer’s Implementation Workbook specifies that the SMTP reply is “outlook.microsoft.com:587”. What correction should be made for array initialization to be successful?

A.

Provide username and password.

B.

Prefix the URL with “https://”.

C.

Remove the port number.

Full Access
Question # 49

Which Purity command can be used to validate I/O is balanced across initiators?

A.

purehost list --balance

B.

purehost iobalance --check

C.

purehost monitor --balance

Full Access
Question # 50

Where can the NVRAM on a FlashArray//E be located?

A.

Distributed across DFMes

B.

Distributed across DFMDs

C.

Within the dedicated NVRAMS

Full Access
Question # 51

An Implementation Engineer is going on site to complete a data pack evacuation and perform a hardware NDU. At what step should the Implementation Engineer contact support for assistance?

A.

After removing the fully evacuated drives before proceeding with the hardware NDU

B.

After removing the Old drives and inserting any new ones

C.

When the hardware NDU has been completed

Full Access
Question # 52

For FlashArray//XL, which PCIe card slot is reserved for control upgrades?

A.

5

B.

6

C.

7

Full Access
Question # 53

What are the default replication ports on all three rack unit FlashArray models?

A.

ETH2 and ETH3

B.

ETH4 and ETH5

C.

ETH0 and ETH1

Full Access
Question # 54

What are the default replication ports on all three rack unit (3U) FlashArray models?

A.

ETH0 and ETH1

B.

ETH2 and ETH3

C.

ETH4 and ETH5

D.

ETH6 and ETH7

Full Access
Question # 55

An Implementation Engineer is upgrading a FlashArray//X50R3 to an //X50R4. The array has 10 SAS and 10 DirectFlash modules in the chassis. What type of controller is required to complete the upgrade?

A.

FLASHARRAY//XC50 R4, SE

B.

FLASHARRAY//XC50 R4, NS

C.

FLASHARRAY//XC50 R4

Full Access
Question # 56

What command should the Implementation Engineer run to configure a proxy?

A.

purearray setattr --proxy https://yourproxyserver:1234

B.

puresetup proxy https://yourproxyserver:1234

C.

purearray configure --proxy url https://example.proxy.server

D.

purenetwork proxy set https://yourproxyserver:1234

Full Access
Question # 57

During a FlashArray//X to FlashArray//XL hardware upgrade, when should the Implementation Engineer insert the DFMd modules into the FlashArray//XL?

A.

After booting the FlashArray//XL into shelf mode

B.

As part of initial install before power-on

C.

Immediately following the purity software upgrade

Full Access
Question # 58

A customer has a FlashArray X20R3 with 22/22 data packs in the chassis at 80% space usage and wishes to swap one of the data packs for a 45TB pack. What step needs to be taken to facilitate this consolidation?

A.

Send a DirectFlash Shelf without any additional capacity.

B.

Send a DirectFlash Shelf with a 63TB of temporary extra capacity.

C.

Reduce array space usage to allow for the evacuation of the 22TB packs.

Full Access
Question # 59

When transforming an array from SAS to NVMe with the Evergreen XFORM upgrade, when should a swing shelf be installed?

A.

When the chassis is populated with two data packs

B.

When there is insufficient free space to evac capacity.

C.

When the array is half populated with Flash Modules

Full Access
Question # 60

The customer has completed the installation document and has stated that the proxy server address is “10.24.18.120”. What additional information is required?

A.

Credentials and port number

B.

Protocol prefix and credentials

C.

Protocol prefix and port number

Full Access
Question # 61

After completing an installation, the customer requests to configure replication IP settings. Where in the GUI does the customer need to navigate in order to do this?

A.

Storage > Replication

B.

Storage > Array Connections

C.

Settings > Network

D.

System > Configuration

Full Access
Question # 62

When configuring File Services, which service type must be assigned to the virtual network interface in the purenetwork configuration?

A.

iSCSI

B.

Replication

C.

File

D.

Management

Full Access
Question # 63

At the completion of an upgrade, what command should the Implementation Engineer run to send phonehome logs?

A.

purearray phonehome --send-logs

B.

purelogs --send-all

C.

purearray phonehome --send-today

Full Access
Question # 64

Which NVRAM bays are always populated on the FlashArray//XR2/3?

A.

0-1

B.

0-2

C.

0-3

D.

1-2

Full Access
Question # 65

By default, which network interface does FA File use to resolve and reach domain controllers?

A.

replication

B.

filevip vif

C.

management

Full Access
Question # 66

How many power connections are required for the FlashArray//XL chassis?

A.

2

B.

4

C.

6

D.

8

Full Access
Question # 67

An Implementation Engineer completes an installation running 6.x and needs to log back into the array to run final health checks. After rebooting the controllers, which user account should the Implementation Engineer use to log in?

A.

pureuser

B.

puresetup

C.

pureeng

Full Access
Question # 68

When adding a data pack into a FlashArray chassis or a DFS shelf, the drives show "unrecognized" status when running puredrive list.

What is the cause of this status on the newly inserted drives?

A.

The Purity version of the FlashArray/DFS is incompatible with the new drives.

B.

The drives exceed the max space supported for the controller model.

C.

There is a hardware fault that needs to be corrected.

D.

The drives have not yet been logically admitted into the array.

Full Access
Question # 69

Prior to installing a new FlashArray controller, which terminal display settings must the Implementation Engineer configure?

A.

8-N-1, Xon/Xoff flow control, 115,200 baud

B.

8-E-1, Xon/Xoff flow control, 115,200 baud

C.

8-N-1, Xon/Xoff flow control, 38,400 baud

Full Access
Question # 70

What is the the minimum supported capacity requirement for a FlashArray//XL170R5?

A.

115TB

B.

135TB

C.

90TB

Full Access