Summer Special Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: myex65

Home > Pure Storage > FAIS > FlashArray-Implementation-Specialist

FlashArray-Implementation-Specialist Pure Certified FlashArray Implementation Specialist (FAIS) Exam Question and Answers

Question # 4

Which command should an Implementation Engineer use to allow Support access to an array?

A.

purearray connect --remoteassist

B.

purearray remoteassist

C.

purearray remoteassist --connect

Full Access
Question # 5

A FlashArray arrives with Purity 5.3.8 applied out of the factory. The account team requests that the array configured with Purity 6.1.21. Which steps should the Implementation Engineer select to meet this requirement?

A.

Create a bootable USB stick from the 6.1.21 ISO file and reimage both controllers with it.

B.

Copy the PPKG and SHA1 files to a USB stick and upgrade the controllers.

C.

Configure the array with the current code and then open a case with Support to upgrade.

Full Access
Question # 6

An Implementation Engineer is setting up a customer environment and has specified a number of NTP servers.

Which command should the Implementation Engineer run to list the NTP servers that have been configured?

A.

puredns list --ntpserver

B.

purenetwork list --ntpserver

C.

purearray list --ntpserver

Full Access
Question # 7

For FlashArray//XL, which 2 PCIe slots should be used for DFS connectivity?

A.

0 and 4

B.

0 and 6

C.

1 and 7

Full Access
Question # 8

What is the rack unit height of a FlashArray//XL?

A.

4

B.

5

C.

6

Full Access
Question # 9

After performing a hardware upgrade from an //M20R2 to a //X20R3-EMEZZ, a customer wants to add a Direct Flash Modules data pack to replace the existing SAS Chassis Data Packs (2x 20TB DPs). What extra hardware is required?

A.

DFM Swing shelf

B.

SAS Swing shelf

C.

4-port ETH card

Full Access
Question # 10

Before installing array rails, where should the cage nuts be placed?

A.

Lowest square of lowest RU

B.

Lowest square of top RU

C.

Top square of the lowest RU

Full Access
Question # 11

When transforming an array from SAS to NVMe with the Evergeen XFORM upgrade, when should a swing shelf be installed?

A.

When the chassis is populated with two data packs

B.

When there is insufficient free space to evac capacity.

C.

When the array is half populated with Flash Modules

Full Access
Question # 12

What command should be used to check the shelf cable connections?

A.

purearray list --shelf

B.

purehw list --enclosures

C.

storage_view.py config

Full Access
Question # 13

What upgrade scenario required an upgrade of power supplies?

A.

X10 > X50

B.

X50 > X70

C.

X50R2 > X50R3

Full Access
Question # 14

A FlashArray//XR2/3 has an Ethernet mezzanine (EMEZZ), what are the interface names of the ports on the mezzanine?

A.

ETH6, ETH7, ETH8, and ETH9

B.

ETH8, ETH9, ETH10, and ETH11

C.

ETH10, ETH11, ETH12, and ETH13

Full Access
Question # 15

Prior to running the puresetup newarray command, which command should an Installation Engineer run on a new install of an //XR4 array?

A.

pureboot list

B.

cobalt_check.py

C.

purehw list

Full Access
Question # 16

What hardware should the Implementation Engineer find in the upgrade kit in order to perform an //X to //XL NDU?

A.

2 QSFP cables / 3 Mellanox cards / 20 DFMDs

B.

3 QSFP cables / 4 Mellanox cards / 10 DFMDs

C.

4 QSFP cables / 2 Mellanox cards / 20 DFMDs

Full Access
Question # 17

A customer needs to have arrays installed and configured with ActiveCluster and ETH replication. The installation document contains 3 IP addresses. How many additional IP addresses are needed?

A.

4

B.

5

C.

6

Full Access
Question # 18

What are the interface names for a 4-port FC card in slot 1 in an XR2/3 array?

A.

FC0, FC1, FC2, and FC3

B.

FC4, FC5, FC6, and FC7

C.

FC5, FC6, FC7, and FC8

Full Access
Question # 19

A dark site customer requests an evacuation of SH01 on a FlashArray/M50. What is an appropriate next step?

A.

Use the evac_checks script.

B.

Ensure that usable capacity is less than 80%.

C.

Ensure that usable capacity is less than 90%.

Full Access
Question # 20

An Implementation Engineer is performing a capacity consolidation on an X50R2 that is 83% full. The starting config is X50R2-20/10-22/0. The end config is X50R2-91/0. What steps should the Implementation Engineer follow to complete the work?

A.

Evac the chasses drives, install the new 91TB chassis data pack, and evac SH0.

B.

Move the 20TB chassis DP to SH0, install the new 91TB chassis DP, evac the 10TB chassis DP, and evac SH0.

C.

Evac SH0, evac the 20TB chassis DP, install the new 91TB DP, and evac the 10TB chassis DP.

Full Access
Question # 21

An Implementation Engineer is onsite to install a new DFM data pack (DP) to CH0.BAY10-CH0.BAY19 of a FlashArray.

After adding the drives to the chassis, which command should the Implementation Engineer run to verify if the new DP is in a wide write group?

A.

find_drive.py

B.

puredb list drives

C.

puredrive list --pack CH0.BAY10

Full Access
Question # 22

In a situation where FC cards need to be re-used during a controller upgrade, which is a valid transfer path?

A.

M > XR2

B.

M > XR2/3

C.

XR2 > XR3

Full Access