Labour Day Sale - Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: mxmas70

Home > Exin > EPI Data Centre > CDCP

CDCP Certified Data Centre Professional (CDCP) Question and Answers

Question # 4

What is the main risk for a data centre when the water supply fails?

A.

Failure to the water supply could result in IT failure and/or denial of access to operate.

B.

Failure to the water supply could result in DX cooling systems to fail.

C.

Failure to the water supply could cause issues for the cooling of back-up generators.

D.

Failure to the water supply could result in sudden changes of the relative humidity in the Computer room.

Full Access
Question # 5

The UPS vendor is offering the latest model of their UPS to you. The vendor indicates that the UPS is categorized as VFD class.

Is this UPS a fit for your mission-critical data centre?

A.

Yes

B.

No

C.

Yes, but only if you oversize the battery bank with 10%.

D.

Yes, but only if they install it with a 12-pulse rectifier.

Full Access
Question # 6

What is the recommended location for the Isolation Transformer in relation to the ICT-Equipment location?

A.

The isolation transformer should be as close as possible to the ICT equipment but taking into account potential EMF.

B.

The isolation transformer should be as far away as possible to the ICT equipment to avoid potential EMF.

C.

The isolation transformer has to be installed within the power entry point of the building due to electrical code (regulation) requirements.

D.

The isolation transformer should be installed within the rack in which the ICT equipment has been installed.

Full Access
Question # 7

Which Class of Fires involves cooking appliances?

A.

Class A

B.

Class B

C.

Class C

D.

Class K

Full Access
Question # 8

What is the purpose of a service corridor?

A.

To create a secure and conditioned environment where media can be stored in a controlled manner.

B.

It is a generic name for pathways leading to other rooms that contains facility supporting equipment like the UPS room, battery room, generator room etc.

C.

It provides a safe, vented and secure area where standby generators can operate safely.

D.

It provides a secure area where supporting facilities can be serviced and monitored on a 24x7 basis without disturbing the computer room.

Full Access
Question # 9

Mean time between failures is best considered a measure of:

A.

Size

B.

Cost

C.

Duration

D.

Reliability

Full Access
Question # 10

Which Class of Fires involves ordinary combustible materials such as paper, wood and cloth?

A.

Class A

B.

Class B

C.

Class D

D.

Class K

Full Access
Question # 11

What is the minimum clearance space required below water sprinkler heads and nozzles of gas-based fire suppression systems?

A.

46 cm / 18 inches

B.

64 cm / 25 inches

C.

60 cm / 24 inches

D.

120 cm / 47 inches

Full Access
Question # 12

Which one of the following does a Physical Infrastructure consists of in a Data Centre?

A.

Hub

B.

Switch

C.

Rack

D.

Server

Full Access
Question # 13

Which type of Fire Detection Device is recommended for protecting a Data Center?

A.

Heat detector

B.

Smoke detector

C.

Flame detector

D.

None of the above

Full Access
Question # 14

An optical fiber cable comes with the specifications 50/125 um.

What do the numbers represent?

A.

The first number represents the distance for a 10 Gb/s connection; the second number represents the distance for a 1 Gb/s connection.

B.

The first number represents the diameter of the core; the second number represents the diameter of the cladding in microns.

C.

The first number represents the diameter of the core; the second number represents the actual diameter cable including the buffer and jacket.

D.

The first number represents the required distance to single-phase power cabling; the second number represents the required distance to three-phase cabling.

Full Access
Question # 15

Which one of the following is used in Measuring Business Value?

A.

Regeneration Cost

B.

Scalability

C.

Reliability

D.

Upfront Cost

Full Access
Question # 16

is the arithmetic mean of time between the failing and the subsequent running of the system in a particular time period.

A.

MTBF

B.

MCBF

C.

MLBF

D.

MTTR

Full Access
Question # 17

Which design consideration should be implemented with an Inergen-based fire suppression system?

A.

Install protective covers around the nozzles to avoid accidental gas dumps.

B.

Install the gas containers (tanks) close to the data centre.

C.

To use Inergen only for fires which are not related to electrical power.

D.

Pressure relief valves are required in the room that needs protection.

Full Access
Question # 18

is the ability of a system or component to perform its required functions under stated conditions for a specified period of time.

A.

Scalability

B.

Agility

C.

Reliability

D.

Availability

Full Access
Question # 19

Which is the most damaging type of floor load?

A.

Concentrated Load / Point Load (CP/ PL)

B.

Uniformly Distributed Load (UDL)

C.

Rolling Load (RL)

D.

All loads are equally damaging to raised floor tiles

Full Access
Question # 20

How many monitoring points should be used in Temperature Measurement?

A.

1

B.

2

C.

3

D.

4

Full Access
Question # 21

Which type of Humidifier rapidly vibrates waster to create a fog or mist?

A.

Infrared Humidifier

B.

Water Canister Humidifier

C.

Steam Canister Humidifier

D.

Ultrasonic Humidifier

Full Access